E17
Kospel
Room Thermostat / External Control Fault
Display shows E17; furnace may not respond to thermostat or room controller.
Advertisements
Possible Causes
Open circuit in room thermostat wiring, Incorrect thermostat settings, Faulty external controller, Misconfigured control parameters on PCB
How to Fix / Troubleshooting
Safety: Turn off power before working on low-voltage control wiring.
- Check thermostat wiring: Inspect the two-core cable from the room thermostat or Kospel controller to the furnace terminals. Tighten loose screws and repair damaged cable.
- Bypass test (if allowed): Temporarily bridge the thermostat terminals at the furnace to simulate a heat demand. If the furnace starts, the thermostat or its wiring is faulty.
- Verify settings: Ensure the thermostat is set to heating mode and the setpoint is above room temperature.
If E17 remains even with a bypass, the control board input may be defective and require replacement.