Kospel
Short Cycling
Furnace frequently starts and stops (short cycling) even when heating demand is constant.
Advertisements
Possible Causes
Oversized furnace for system, Incorrect control settings, Blocked or closed radiators, Faulty temperature sensor placement
How to Fix / Troubleshooting
Safety: No special hazards beyond normal; do not remove combustion covers while running.
- Open radiators: Ensure enough radiators or heating loops are open to absorb the furnace output.
- Adjust settings: Lower the flow temperature setpoint or adjust the heating curve on the Kospel controller to reduce overshoot.
- Check pump speed: Increase pump speed to improve heat distribution.
If short cycling persists, a heating professional should review system design and possibly adjust Kospel control parameters more deeply.
Advertisements
Repair Difficulty
Easy
2/5