Luxaire
Ignition Sequence Interruption
Inducer motor runs but burners do not light; no error code displayed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty pressure switch not signaling closed, Loose ignitor wiring, Faulty control board timing, Weak ignitor
How to Fix / Troubleshooting
Safety: Turn off power and gas before inspecting ignition components.
Steps to check:
- Observe sequence: Through the sight glass, confirm whether the ignitor glows after the inducer starts. If not, check ignitor wiring harness.
- Inspect pressure switch tubing: Ensure tubing is intact and connected; a switch that does not close will prevent ignition.
A technician should test pressure switch operation, ignitor voltage, and control board outputs.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Pressure Switch or Hot Surface Ignitor