Maytag
Open Thermostat Circuit
Thermostat calls for heat but furnace does nothing; no inducer, no blower, LED shows normal idle.
Advertisements
Possible Causes
Broken W (heat call) wire, Loose thermostat connection, Faulty thermostat, Tripped low-voltage fuse on control board
How to Fix / Troubleshooting
Safety: Turn off power before working on low-voltage wiring.
Steps to check:
- Check thermostat: Replace batteries if applicable and ensure settings are correct.
- Inspect wiring at furnace: Confirm the W wire is securely attached to the W terminal on the control board and not broken.
- Test with jumper: With power off, temporarily connect a jumper between R and W at the control board. Restore power. If the furnace starts, the thermostat or its wiring is likely faulty.
When to call a technician: If the furnace does not respond even with R-W jumpered, professional diagnosis of the control board and safeties is needed.