E1
Miller
Ignition Failure (Retries Exceeded)
Miller furnace digital display shows E1 and shuts down.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty burners preventing proper ignition, Weak ignitor, Low gas pressure, Faulty gas valve
How to Fix / Troubleshooting
Safety: Turn off gas and power. Work in a well-ventilated area and avoid open flames.
- Clean burners: Remove the burner assembly and clean each burner with a brush and compressed air. Ensure crossover ports between burners are clear.
- Inspect ignitor: Check for cracks or white spots. Replace if suspect.
- Check gas supply: Confirm gas shutoff valves are open and other gas appliances operate normally. If you suspect low pressure, contact your gas provider or a licensed technician.
- Test gas valve: During ignition, verify 24V at the gas valve. If voltage is present but no gas flow, replace the gas valve.
Advertisements
Repair Difficulty
Hard
4/5