E051
Navien Thermostat / Room Controller Communication Fault

Navien furnace shows E051, heating demand not recognized or unit does not respond to thermostat

Advertisements

Possible Causes

Incorrect thermostat wiring, Open circuit in room controller cable, Incompatible thermostat type, Faulty room controller

How to Fix / Troubleshooting

Safety: Turn off power before working on thermostat or low-voltage wiring.

  • Verify thermostat type: Ensure the thermostat or Navien room controller is compatible with the furnace model and wired for the correct control type (e.g., dry contact, 24V).
  • Check wiring at thermostat: Remove the thermostat from its base and inspect the wiring. Confirm that the wires are connected to the correct terminals as per Navien's wiring diagram. Tighten any loose connections.
  • Check wiring at furnace: At the Navien control board, verify that the thermostat/room controller wires are landed on the correct low-voltage terminals and are secure.
  • Test continuity: With power off, disconnect both ends of the thermostat cable and test continuity of each conductor with a multimeter. Replace the cable if any conductor is open or shorted.
  • Bypass test (if allowed by manual): Temporarily install a jumper across the call-for-heat terminals at the furnace to see if the unit responds. If it does, the thermostat or its wiring is suspect. Replace the thermostat or room controller as needed.