B2
Nibe Brine circulation pump fault

B2 alarm, brine/ground loop pump not running, A4 alarms may also appear

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized brine pump, air in brine circuit, blocked brine filter, failed pump electronics

How to Fix / Troubleshooting

Safety: Isolate power and close brine valves before opening any pump or filter. Wear gloves and eye protection.

  • Check pump operation: With power on and a heat demand present, feel the brine pump for vibration. If none, check its power supply and fuses.
  • Bleed air: Use the bleed points on the brine circuit to remove trapped air. Follow Nibe's brine handling instructions.
  • Clean brine filter: Shut valves, remove the filter cap, clean the strainer, and refit. Open valves and bleed again.
  • Reset alarm: Restore power and clear the B2 alarm. If the pump still does not run, it likely needs replacement.