Nibe
Insufficient heating output / undersized or misconfigured system
Furnace runs but radiators or underfloor heating remain lukewarm or cold
Advertisements
Possible Causes
Incorrect curve setting on Nibe controller, air in heating system, partially closed balancing valves, clogged system filter
How to Fix / Troubleshooting
Safety: Allow system to cool before bleeding radiators. Use a cloth to catch water.
- Bleed radiators and manifolds: Starting from the lowest floor, bleed each radiator or underfloor manifold to remove trapped air. Top up system pressure as needed.
- Open valves fully: Ensure all radiator valves and any zone valves are fully open while troubleshooting.
- Clean filters: Locate and clean the heating system filter or strainer near the Nibe unit.
- Adjust heating curve: In the Nibe menu, increase the heating curve slope slightly and observe if room temperatures improve over several hours. Do not make large changes at once.
If comfort is still poor, a heating engineer should check system design and balancing.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements