Nibe
Underheating / control undershoot
Nibe furnace display shows normal operation but room remains too cold
Advertisements
Possible Causes
Heating curve too low, incorrect sensor calibration, undersized emitters, partially closed TRVs
How to Fix / Troubleshooting
Safety: None specific beyond normal heating system precautions.
- Open TRVs fully: Temporarily open all thermostatic radiator valves to allow maximum flow.
- Increase heating curve: Raise the heating curve slope slightly in the Nibe controller and monitor room temperature over 24 hours.
- Check sensor reading: Compare room sensor reading with an accurate thermometer; adjust calibration in the menu if available.
If the system still cannot reach setpoint in cold weather, consult an installer about system sizing.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements