12
Payne Blower On After Power Up / Low Heat Demand Memory

Status LED shows code 12 (one short flash, two long flashes) after a call for heat; furnace may or may not complete a cycle.

Advertisements

Possible Causes

Recent power interruption during a heat cycle, blower off-delay in progress, control board memory indication, marginal control board, thermostat short cycling

How to Fix / Troubleshooting

Safety first: Turn off power before removing panels. Blower and inducer can start automatically.

On many Payne furnaces, code 12 indicates the blower ran after power-up or that the control is reporting a previous low-heat demand condition.

  • Allow furnace to complete a full cycle: Set thermostat to HEAT and raise setpoint. Let the furnace run until it satisfies the thermostat and shuts off. Observe if the code clears to steady LED (normal operation).
  • Check blower off-delay: The blower may continue to run after burners shut off. This is normal. Wait 60–120 seconds to see if the blower stops and the code clears.
  • Inspect thermostat operation: If the thermostat is rapidly cycling the furnace (on/off every few minutes), adjust the cycle rate or replace the thermostat.
  • Power reset: Turn off power for 1 minute, then restore. If the furnace operates normally and no other codes appear, no repair is needed.
  • If code persists with erratic behavior: Inspect the control board for burn marks or swollen components. If present, the integrated furnace control (IFC) may need replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Integrated Furnace Control Board