32
Payne Low Heat or Blower Fault / Blower Failure to Start

Status LED flashes code 32 (three short, two long). Furnace may overheat and shut down; blower may not start on time.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed blower motor, failed blower run capacitor, loose blower wiring, seized blower wheel, defective control board fan relay

How to Fix / Troubleshooting

Safety first: Turn off power before reaching into the blower compartment. The blower can start unexpectedly.

  • Check blower operation: Set thermostat fan switch to ON. If the blower does not run, suspect a blower motor or capacitor issue.
  • Inspect blower wheel: Remove the blower compartment door. Try to spin the blower wheel by hand (power off). It should spin freely. If it is stiff or scraping, clean or replace the wheel and check for obstructions.
  • Test capacitor: Locate the blower run capacitor (metal can with two or three terminals). If it is bulged or leaking, replace it with the same µF rating and voltage.
  • Check motor wiring: Verify all motor leads are firmly connected to the control board or fan relay. Look for burned connectors.
  • Measure motor voltage: With power on and a call for fan/heat, carefully measure voltage at the motor leads. If proper voltage is present but the motor does not run, replace the blower motor.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Blower Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements