E06
Ravenheat
Flow Temperature Sensor Fault (NTC Sensor Error)
Furnace shows E06 and shuts down, often related to temperature sensor readings.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open-circuit or shorted NTC sensor, Loose sensor wiring or connector, Sensor not properly clipped to pipe, Faulty main PCB input
How to Fix / Troubleshooting
Safety: Isolate power before removing the front cover. Components may be hot; allow cooling time.
User checks:
- Power-cycle the unit and attempt a reset. If E06 returns immediately, a sensor or PCB fault is likely.
Technician checks:
- Locate the flow NTC sensor on the flow pipe leaving the heat exchanger.
- Check the sensor wiring harness and connector for corrosion, loose pins, or damage.
- Measure the resistance of the NTC at a known temperature and compare with Ravenheat resistance tables.
- If readings are out of range, replace the NTC sensor. If readings are correct, test continuity back to the PCB and verify PCB input.
Do not bypass temperature sensors; they are essential safety controls.