E08
Ravenheat Mains Supply / Polarity / Earth Fault

Furnace shows E08 and will not operate, often after a power surge or wiring disturbance.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect live/neutral polarity, Missing earth connection, Supply voltage out of range, Internal PCB power supply fault

How to Fix / Troubleshooting

Safety: Electrical work must comply with local regulations. If you are not competent, contact an electrician or heating engineer.

User checks:

  • Ensure the fused spur is switched on and the fuse is intact.
  • Check that no extension leads or multi-plug adapters are used to power the furnace.
  • Power-cycle the unit and see if E08 clears.

Technician checks:

  • Verify correct polarity (L/N) and earth continuity at the appliance terminals.
  • Measure supply voltage and ensure it is within Ravenheat specifications.
  • Inspect the main PCB for visible damage, burn marks, or swollen capacitors.
  • Test surge protection devices and replace the PCB if the internal power supply is faulty.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements