E18
Ravenheat
External Safety Interlock / Condensate Pump Fault
Furnace shows E18, often associated with condensate pump (if fitted) or external safety devices.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Condensate pump failure or float switch activation, External safety thermostat open, Wiring fault on safety loop, Blocked condensate line causing pump overflow
How to Fix / Troubleshooting
Safety: Isolate power. Water and electricity are a hazardous combination; take care around condensate pumps.
User checks:
- If a separate condensate pump is installed, check if it is running or making unusual noises.
- Ensure the pump discharge pipe is not kinked or blocked.
Technician checks:
- Test the condensate pump operation and float switch; replace if faulty.
- Verify continuity of the external safety loop wiring.
- Clear any blockages in the condensate discharge line.
- Reset any external safety thermostats once the cause has been rectified.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Condensate Pump
Check Price on Amazon
We may earn a commission from links on this page.