E22
Remeha
Return temperature too high / insufficient heat dissipation
Furnace shows E22, burner stops and restarts frequently
Advertisements
Possible Causes
Oversized furnace for system, Low system flow rate, Closed thermostatic radiator valves, Incorrect pump speed setting
How to Fix / Troubleshooting
Safety first: Surfaces may be hot. Isolate power before adjusting internal components.
- Open radiators: Ensure that enough radiators or heating circuits are open to dissipate the furnace output. Avoid closing all TRVs in the property.
- Check pump settings: On models with adjustable pump speed, set the pump to a higher speed to increase flow.
- Hydraulic balancing: Have a technician balance the system to ensure even flow through all circuits.
- Adjust maximum output: In the installer menu, reduce the maximum central heating output to better match the system load.
- Monitor operation: After adjustments, observe whether E22 and short cycling are reduced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements