Remeha
Unstable flame / marginal ignition
Furnace starts but shuts down after a few seconds without showing an error code
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak ignition spark, Incorrect electrode gap, Low gas pressure, Partially blocked burner
How to Fix / Troubleshooting
Safety first: Gas and ignition components must be serviced by qualified technicians.
- Observe ignition: Through the sight glass, observe whether the flame is stable or lifts off and goes out shortly after ignition.
- Inspect electrodes: Check ignition and ionisation electrodes for wear, cracks, or incorrect positioning. Adjust or replace as needed.
- Clean burner: Remove and clean the burner surface to ensure even gas distribution.
- Check gas pressure: A technician should measure inlet and burner pressure and correct any supply issues.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Ignition Electrode
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements