41
Rheem
Blower Motor Fault / Incorrect Blower Operation
Status LED flashes 4 short and 1 long (41); furnace may overheat or underheat
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed ECM blower motor, Faulty blower run capacitor (PSC motors), Loose blower wiring, Control board fan relay failure
How to Fix / Troubleshooting
Safety first: Turn off power before working on the blower assembly.
- Check blower wheel: Inspect for obstructions or heavy dust buildup that could overload the motor.
- Test capacitor (PSC): If your Rheem furnace uses a PSC motor, test the run capacitor with a capacitance meter and replace if out of tolerance.
- Inspect ECM module (if equipped): For ECM motors, check the motor module connector for corrosion or loose pins. Many Rheem ECM motors require replacement of the entire motor/module assembly if failed.
- Verify board output: Confirm the control board is sending the correct voltage or signal to the blower motor when a call for heat or fan is present.
Because blower motors are heavy and wiring is complex, many homeowners choose professional replacement.
Advertisements
Repair Difficulty
Hard
4/5