A05
Riello Internal Control Box Failure

Burner control indicates lockout due to internal fault, no start sequence, red light on immediately

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective Riello burner control box electronics, Voltage spikes or incorrect supply voltage, Internal relay failure, Moisture ingress into control module

How to Fix / Troubleshooting

Safety: Disconnect power at the breaker and verify no voltage is present before touching wiring.

Steps:

  • Check supply voltage: Use a multimeter to confirm correct line voltage at the burner (typically 120V or 230V depending on model). Correct any wiring or breaker issues.
  • Inspect connectors: Remove and reseat the multi-pin plug from the Riello control box. Look for corrosion, burning, or loose pins.
  • Check for moisture: Inspect the control box and burner compartment for signs of water leaks or condensation. Correct any source of moisture.

If A05 persists and all external conditions are normal, the control box is likely defective and should be replaced with the exact Riello replacement part by a qualified technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Riello Burner Control Box