A11
Riello Open Safety Circuit

Burner locks out with code indicating safety chain open (limit, door switch, or external safety open)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped high limit switch, Open door interlock switch, Faulty wiring in safety loop, External safety device (spill switch, low water cutoff) open

How to Fix / Troubleshooting

Safety: Do not bypass safety devices. Turn off power before testing continuity.

Steps:

  • Check manual reset safeties: Locate any manual reset limits or spill switches on the furnace or vent connector. Press the reset button once.
  • Inspect door switch: Ensure the burner access door is fully closed and the door switch actuator is engaged.
  • Test continuity: Using a multimeter, check continuity through each safety device in the chain. Replace any switch that remains open at normal temperature.
  • Inspect wiring: Look for broken or disconnected wires in the safety loop from the furnace to the Riello burner.

If A11 persists and all safeties test good, the control box input circuit may be faulty.