A11
Riello
Open Safety Circuit
Burner locks out with code indicating safety chain open (limit, door switch, or external safety open)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped high limit switch, Open door interlock switch, Faulty wiring in safety loop, External safety device (spill switch, low water cutoff) open
How to Fix / Troubleshooting
Safety: Do not bypass safety devices. Turn off power before testing continuity.
Steps:
- Check manual reset safeties: Locate any manual reset limits or spill switches on the furnace or vent connector. Press the reset button once.
- Inspect door switch: Ensure the burner access door is fully closed and the door switch actuator is engaged.
- Test continuity: Using a multimeter, check continuity through each safety device in the chain. Replace any switch that remains open at normal temperature.
- Inspect wiring: Look for broken or disconnected wires in the safety loop from the furnace to the Riello burner.
If A11 persists and all safeties test good, the control box input circuit may be faulty.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
High Limit Thermostat
Check Price on Amazon
We may earn a commission from links on this page.