E01
Riello
General Ignition Failure (Electronic Code)
Electronic display on Riello furnace shows E01, burner does not start, lockout condition
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
No fuel to burner, Ignition transformer failure, Incorrect electrode setting, Blocked nozzle or fuel filter
How to Fix / Troubleshooting
Safety: Turn off electrical power and close the oil shutoff valve before servicing.
Steps:
- Check fuel level and valves: Confirm oil tank is not empty and all valves to the Riello burner are open.
- Replace oil filter: Change the oil filter at the tank or near the burner if dirty.
- Inspect ignition system: Check ignition transformer and electrodes for damage. Clean and set electrode gap per Riello specs.
- Replace nozzle: Install a new, correct-spec Riello nozzle if blockage is suspected.
If E01 remains, professional diagnosis of the control and pump is recommended.
Advertisements
Repair Difficulty
Hard
4/5