E01
Riello General Ignition Failure (Electronic Code)

Electronic display on Riello furnace shows E01, burner does not start, lockout condition

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

No fuel to burner, Ignition transformer failure, Incorrect electrode setting, Blocked nozzle or fuel filter

How to Fix / Troubleshooting

Safety: Turn off electrical power and close the oil shutoff valve before servicing.

Steps:

  • Check fuel level and valves: Confirm oil tank is not empty and all valves to the Riello burner are open.
  • Replace oil filter: Change the oil filter at the tank or near the burner if dirty.
  • Inspect ignition system: Check ignition transformer and electrodes for damage. Clean and set electrode gap per Riello specs.
  • Replace nozzle: Install a new, correct-spec Riello nozzle if blockage is suspected.

If E01 remains, professional diagnosis of the control and pump is recommended.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Oil Nozzle
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements