E05
Riello
Air Pressure / Fan Proving Fault
Display shows E05, indicating air pressure switch or fan proving fault
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked air intake, Faulty air pressure switch, Weak or failed combustion fan motor, Cracked or disconnected pressure tubing
How to Fix / Troubleshooting
Safety: Disconnect power before working on the fan or pressure switch.
Steps:
- Clear intake: Inspect and clean the combustion air intake and any screens.
- Check tubing: Replace brittle or loose tubing to the pressure switch. Ensure ports are not plugged.
- Test switch: Use a multimeter to verify the switch closes when the fan runs. Replace if it does not.
If E05 persists with a good switch and clear intake, the fan motor may need replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Air Pressure Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements