Riello
No-Start Condition
Furnace will not start at all, no burner operation, no attempt to ignite, but power is present
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped safety limit or rollout switch, Faulty thermostat or no call for heat, Blown fuse on control board, Loose wiring to Riello burner
How to Fix / Troubleshooting
Safety: Turn off power before opening the furnace cabinet.
Steps:
- Verify thermostat: Set thermostat to heat and raise setpoint. Confirm 24V (or control signal) is reaching the furnace control.
- Check fuses: Inspect any inline fuses or board-mounted fuses and replace only with identical ratings.
- Inspect safety switches: Reset any manual rollout or high limit switches. If they trip again, stop and call a technician.
- Check burner plug: Ensure the Riello burner plug is fully seated in the control socket and wiring is intact.
Advertisements
Repair Difficulty
Medium
3/5