Possible Causes

Tripped safety limit or rollout switch, Faulty thermostat or no call for heat, Blown fuse on control board, Loose wiring to Riello burner

How to Fix / Troubleshooting

Safety: Turn off power before opening the furnace cabinet.

Steps:

  • Verify thermostat: Set thermostat to heat and raise setpoint. Confirm 24V (or control signal) is reaching the furnace control.
  • Check fuses: Inspect any inline fuses or board-mounted fuses and replace only with identical ratings.
  • Inspect safety switches: Reset any manual rollout or high limit switches. If they trip again, stop and call a technician.
  • Check burner plug: Ensure the Riello burner plug is fully seated in the control socket and wiring is intact.