E17
Roca Configuration / Parameter Fault

Furnace shows sensor calibration or configuration error after board replacement or reset

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect DIP switch settings on PCB, Wrong parameter programming for Roca furnace model, Incompatible replacement board, Corrupted EEPROM

How to Fix / Troubleshooting

Safety first: Disconnect power before adjusting any internal switches or jumpers.

  • Verify model settings: Compare the DIP switch or jumper positions on the control board with the Roca installation manual for your exact model and gas type.
  • Check parameter menu: Enter the installer menu (see manual) and confirm key parameters such as maximum power, pump mode, and sensor configuration are correctly set.
  • Factory reset (if available): Perform a factory reset of the control parameters following Roca’s procedure, then re-enter required settings.
  • Board compatibility: Ensure the replacement PCB part number matches the original and is approved for your furnace model.

Warning: Incorrect configuration can cause unsafe operation. If unsure, have a Roca-authorized technician program the board.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board (PCB)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements