Roca
Overpressure / Safety Valve Discharge
Pressure relief valve discharges water frequently through the safety pipe
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed expansion vessel, Overfilled system, Faulty pressure relief valve, Blocked expansion vessel connection
How to Fix / Troubleshooting
Safety first: Allow the system to cool before working on pressurized components.
- Check system pressure: If cold pressure is above the recommended level, drain some water from a drain cock until it is within range.
- Test expansion vessel: See expansion vessel fault steps; a failed vessel will cause pressure spikes.
- Inspect relief valve: If the valve continues to drip even at normal pressure, it may be fouled by debris and require replacement.
- Check discharge pipe: Ensure the discharge pipe is not blocked or frozen, which can prevent proper operation.
Warning: Never cap or block the pressure relief discharge pipe; it is a critical safety device.