Roca Overpressure / Safety Valve Discharge

Pressure relief valve discharges water frequently through the safety pipe

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed expansion vessel, Overfilled system, Faulty pressure relief valve, Blocked expansion vessel connection

How to Fix / Troubleshooting

Safety first: Allow the system to cool before working on pressurized components.

  • Check system pressure: If cold pressure is above the recommended level, drain some water from a drain cock until it is within range.
  • Test expansion vessel: See expansion vessel fault steps; a failed vessel will cause pressure spikes.
  • Inspect relief valve: If the valve continues to drip even at normal pressure, it may be fouled by debris and require replacement.
  • Check discharge pipe: Ensure the discharge pipe is not blocked or frozen, which can prevent proper operation.

Warning: Never cap or block the pressure relief discharge pipe; it is a critical safety device.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Pressure Relief Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements