Possible Causes

Shorted blower motor windings, Shorted inducer motor, Pinched line-voltage wiring, Oversized or incorrect replacement breaker

How to Fix / Troubleshooting

Safety: Repeated breaker tripping is a fire hazard. Do not keep resetting the breaker without finding the cause.

Steps to check:

  • Visual inspection: With power off, inspect wiring inside the furnace for burnt insulation, loose connections, or wires rubbing on sharp metal edges.
  • Isolate components: A technician can disconnect blower and inducer motors one at a time to identify the faulty component.
  • Verify breaker size: Ensure the breaker amperage matches the Ruud furnace nameplate rating.
  • Call a professional: Motor and wiring shorts require professional testing and replacement.