A06
Sime Flame Signal Too Weak or Absent

Furnace shows an ionization or flame signal error even though the burner appears to be lit.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Contaminated flame sensor, Poor electrical grounding, Reversed polarity on power supply, Faulty control board ionization circuit

How to Fix / Troubleshooting

Safety first: Isolate power and gas before accessing internal components.

  • Clean flame sensor: Remove the flame sensing electrode from the burner. Clean the metal rod with fine abrasive pad to remove soot or oxidation. Reinstall ensuring it is correctly positioned in the flame.
  • Check grounding and polarity: Verify that the furnace is connected to a properly grounded outlet and that live/neutral are not reversed. An electrician may be required to correct wiring.
  • Inspect wiring harness: Check the ionization cable from the electrode to the Sime control board for damage or loose connections. Reseat connectors.
  • Measure flame current (advanced): A technician can measure flame rectification current to confirm if the control board is reading the flame correctly. If the signal is good but the board still faults, the board may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flame Sensor / Control Board
Check Price on Amazon