E03
Sime
Air Pressure Switch / Flue Safety Fault
Furnace displays E03 and stops; often associated with flue or air pressure switch problems.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked flue or air intake, Faulty air pressure switch, Split or blocked pressure tubes, Fan not running
How to Fix / Troubleshooting
Safety first: Turn off power and gas. Do not operate the furnace with a suspected flue fault.
- Check flue terminal and intake: From outside, ensure the Sime flue terminal is clear of obstructions. Remove any debris carefully.
- Inspect pressure tubes: Open the furnace and locate the silicone tubes between the fan and air pressure switch. Check for water, kinks, or splits. Replace or clear as needed.
- Test fan operation: Restore power briefly and call for heat to see if the fan starts. If not, the fan or its power supply may be faulty.
- Replace air pressure switch if needed: If the fan runs and tubes are clear but E03 persists, the switch may be defective and should be replaced by a technician.