E04
Sime Low Water Pressure / Circulation Fault

Furnace displays E04; typically related to low water pressure or water circulation issues on hydronic models.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient system pressure, Air in system, Faulty pressure switch, Leak in heating circuit

How to Fix / Troubleshooting

Safety first: Turn off power before topping up water. Avoid over‑pressurizing.

  • Check pressure gauge: If below the minimum mark, use the filling loop to raise pressure to the recommended cold value.
  • Bleed air: Bleed radiators and high points in the system, then re‑top pressure.
  • Inspect for leaks: Look for visible water around the Sime furnace and radiators. Persistent pressure loss indicates a leak that must be repaired.
  • If pressure is correct but E04 remains: The pressure switch or sensor may be faulty and should be tested and replaced by a technician.