E06
Sime
Return NTC Sensor Error
Furnace displays E06; typically related to return temperature sensor problems.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed return NTC, Loose wiring, Shorted sensor, Control board fault
How to Fix / Troubleshooting
Safety first: Turn off power and let the system cool.
- Locate return NTC: Find the sensor on the return pipe entering the heat exchanger or hydraulic group.
- Inspect and reseat: Check the connector and cable for damage. Reseat the plug.
- Test sensor: Measure resistance and compare to the expected value. Replace if defective.
- Further diagnosis: If the sensor is fine, a technician should test the control board input.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Return NTC Temperature Sensor
Check Price on Amazon