Sime
Poor System Balancing / Air Lock
Radiators or heating zones heat unevenly; some remain cold while others are hot.
Advertisements
Possible Causes
Air trapped in radiators, Closed or partially closed valves, Sludge in pipework, Incorrect pump setting
How to Fix / Troubleshooting
Safety first: Allow radiators to cool slightly before bleeding to avoid scalds.
- Bleed radiators: Starting from the highest floor, use a radiator key to release air until water flows steadily. Re‑top system pressure afterward.
- Check valves: Ensure both the thermostatic and lockshield valves on each radiator are open. Adjust lockshields to balance flow.
- Flush or clean system (technician): If some radiators stay cold at the bottom, sludge may be present and a power flush or chemical clean may be needed.
- Adjust pump speed: Set the Sime pump to an appropriate speed or proportional mode if available.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Circulation Pump / Radiator Valves
Check Price on Amazon
We may earn a commission from links on this page.