10 FLASH
Tappan Flame Sense Error / Flame Present with Gas Off

Furnace shuts down unexpectedly; LED flashes 10 times repeatedly; may coincide with thermostat cycling off.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted flame sensor to ground, moisture on burner assembly, control board flame circuit failure, induced draft motor backdrafting flame

How to Fix / Troubleshooting

Safety: Turn off power and gas before inspecting flame sensor and burners.

Steps:

  • Remove and inspect the flame sensor for cracks in the ceramic insulator or signs of the rod touching metal. Replace if damaged.
  • Check the flame sensor wire for insulation damage or pinched spots where it could short to the furnace chassis. Repair or replace as needed.
  • Inspect the burner compartment for signs of water intrusion or condensation. Correct any venting issues causing moisture.
  • If the sensor and wiring are good, the control board's flame detection circuit may be faulty and require replacement.

Note: This fault is less common; if unsure, have a technician verify with a microamp meter on the flame sensor circuit.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flame Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements