45
Tempstar Control Board Internal Fault / Repeated Lockouts

LED flashes code 45; furnace locks out and may require power cycling to restart.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Multiple unresolved ignition or flame failures, Overheated control board, Defective Tempstar integrated control board, Voltage fluctuations or poor neutral/ground

How to Fix / Troubleshooting

Safety: Turn off power before inspecting electrical connections.

  • Step 1 – Check for prior fault codes: Many Tempstar boards store the last few fault codes. Note any patterns (e.g., repeated 34 or 21) and address those root causes first.
  • Step 2 – Inspect electrical supply: Verify tight connections at the furnace disconnect, breaker, and neutral/ground bar. Loose neutrals can cause erratic board behavior.
  • Step 3 – Check board environment: Ensure the control board compartment is clean and dry. Look for signs of water intrusion from a leaking condensate line or coil pan.
  • Step 4 – Replace control board if persistent: If all underlying issues are corrected and code 45 persists, the Tempstar control board may be internally faulty and should be replaced by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Tempstar Integrated Furnace Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements