Tempstar
Delayed Ignition
Furnace makes loud booming or delayed ignition noise when burners light.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty burners on Tempstar furnace, Misaligned or weak ignitor, Excess gas buildup before ignition, Incorrect gas pressure
How to Fix / Troubleshooting
Warning: Delayed ignition can damage the heat exchanger and pose a safety risk. If the boom is severe, shut down the furnace and call a professional.
- Step 1 – Inspect burners: With power and gas off, remove burners and clean with a brush and compressed air. Ensure crossover ports are clear.
- Step 2 – Check ignitor position: Verify the hot surface ignitor is properly aligned with the burner it lights. Adjust mounting if necessary.
- Step 3 – Replace weak ignitor: If the ignitor glows dimly or slowly, replace it with the correct Tempstar part.
- Step 4 – Professional gas adjustment: Have a licensed technician check and adjust gas pressure and combustion.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Tempstar Burner Assembly
Check Price on Amazon