E19
Thermia Accessory Control Fault

Furnace display shows E19, unit may not start or may shut down when an accessory (humidifier, HRV, etc.) is active.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted humidifier or HRV wiring, Incorrect accessory wiring to Thermia control board, Faulty accessory relay on control board

How to Fix / Troubleshooting

Safety first: Turn off power before working on accessory wiring.

  • 1. Identify connected accessories: Note any humidifiers, HRVs/ERVs, or other devices wired to the Thermia furnace control board.
  • 2. Disconnect accessories: Remove accessory wires from the control board one at a time and test furnace operation. If E19 clears when a specific accessory is disconnected, that device or its wiring is likely at fault.
  • 3. Inspect wiring: Check for shorts to ground or between terminals on the accessory circuits. Repair or replace damaged wires.
  • 4. Verify correct terminals: Ensure accessories are wired only to the designated Thermia accessory terminals and not to thermostat or safety circuits.
  • 5. If E19 persists with all accessories disconnected: The accessory control section of the Thermia control board may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Accessory Control Circuit on Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements