E19
Thermia
Accessory Control Fault
Furnace display shows E19, unit may not start or may shut down when an accessory (humidifier, HRV, etc.) is active.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted humidifier or HRV wiring, Incorrect accessory wiring to Thermia control board, Faulty accessory relay on control board
How to Fix / Troubleshooting
Safety first: Turn off power before working on accessory wiring.
- 1. Identify connected accessories: Note any humidifiers, HRVs/ERVs, or other devices wired to the Thermia furnace control board.
- 2. Disconnect accessories: Remove accessory wires from the control board one at a time and test furnace operation. If E19 clears when a specific accessory is disconnected, that device or its wiring is likely at fault.
- 3. Inspect wiring: Check for shorts to ground or between terminals on the accessory circuits. Repair or replace damaged wires.
- 4. Verify correct terminals: Ensure accessories are wired only to the designated Thermia accessory terminals and not to thermostat or safety circuits.
- 5. If E19 persists with all accessories disconnected: The accessory control section of the Thermia control board may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Accessory Control Circuit on Main Control Board