Thermia Uneven Heating / Poor Air Distribution

Furnace runs but some rooms are too cold while others are too warm.

Advertisements

Possible Causes

Improper duct balancing, Closed or undersized registers, Dirty blower wheel, Low blower speed setting on Thermia control board

How to Fix / Troubleshooting

Safety first: Turn off power before accessing blower components.

  • 1. Check registers and dampers: Make sure all supply registers and return grilles are open. Adjust manual dampers in branch ducts (if present) to direct more air to colder rooms.
  • 2. Inspect filter and blower: Replace a dirty filter. Remove the blower assembly from the Thermia furnace and clean dust from the blower wheel blades to restore airflow.
  • 3. Verify blower speed: On some Thermia models, blower speed taps or settings can be adjusted. A technician can increase heating speed to improve distribution.
  • 4. Consider duct evaluation: If problems persist, have a professional assess duct design and insulation.