STEADY ON
Thermo Pride
Normal Power / No Call for Heat or Board Idle
Status LED is solid on with no flashing pattern, furnace not responding to thermostat.
Advertisements
Possible Causes
Thermostat not calling for heat, Broken thermostat wire, Incorrect thermostat settings, Open safety circuit preventing heat call on Thermo Pride furnace
How to Fix / Troubleshooting
Safety First: Turn off power before moving thermostat wires on the control board.
A steady LED usually means the board has power and is idle.
- Check thermostat: Ensure it is set to HEAT and the setpoint is above room temperature. Replace batteries if applicable.
- Bypass thermostat (advanced): At the furnace control board, briefly jumper R to W with a small piece of insulated wire. If the furnace starts, the thermostat or thermostat wiring is likely faulty.
- Inspect low-voltage wiring: Look for breaks, loose connections, or corrosion at the thermostat and furnace terminals.
- Check safety switches: Ensure the blower door switch is fully depressed by the door. Some models will not respond if the door is off.
When to call a professional: If the furnace does not respond even when R and W are jumpered, further control board or safety circuit diagnosis is needed by a technician.