Thermo Pride Fan Control or Limit Sensor Drift

Furnace blower starts and stops repeatedly without any heat call (fan cycling by itself).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty fan limit switch on older Thermo Pride models, Temperature sensor drift on control board, Residual heat triggering fan, Shorted fan control wiring

How to Fix / Troubleshooting

Safety First: Turn off power before accessing fan/limit controls.

  • Check for residual heat: After a long heat cycle, some fan cycling is normal as the heat exchanger cools. Persistent cycling is not.
  • Inspect fan/limit control (if equipped): On older models with a mechanical fan/limit, ensure the dial moves freely and settings match the Thermo Pride manual.
  • Control board sensor: If the board misreads temperature, it may cycle the fan. Board replacement may be required.
  • Professional diagnosis: Have a technician verify temperature readings and fan control operation.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Fan Limit Switch
Check Price on Amazon