Thermo Pride Flame Sensing Failure

Furnace starts then shuts off within 30 seconds; burners light but go out quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty flame sensor, Poor burner ground, Loose flame sensor wire, Faulty Thermo Pride control board flame circuit

How to Fix / Troubleshooting

Safety First: Turn off power and gas before removing the flame sensor.

  • Clean flame sensor: Remove the sensor and gently clean the metal rod with fine steel wool until shiny. Reinstall and reconnect the wire.
  • Check ground connections: Ensure the burner assembly and control board ground wires are tight and free of corrosion.
  • Inspect sensor wire: Look for cracks, burns, or loose spade connectors. Replace if damaged.
  • Observe operation: Restore power and gas, then call for heat. If the flame still drops out after a few seconds, a technician should test the microamp flame signal and board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flame Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements