Steady On
Trane
Normal Power / No Call or Control Board Locked
Status LED solid on with no flashing, furnace not responding or stuck
Advertisements
Possible Causes
No call for heat from thermostat, Open thermostat circuit, Failed thermostat, Control board firmware lockup
How to Fix / Troubleshooting
Steps to check:
- Verify thermostat settings: Ensure the thermostat is set to HEAT and the setpoint is above room temperature. Replace batteries if applicable.
- Check thermostat wiring: At the furnace, verify the W (heat call) wire is securely connected. Jumper R to W at the furnace terminal strip to simulate a call for heat. If the furnace starts, the thermostat or its wiring is faulty.
- Power cycle: Turn off power to the furnace for 30 seconds, then restore. This can clear minor control board lockups.
When to call a professional: If the furnace does not respond to an R-W jumper, the integrated furnace control board or safety circuits may be faulty and should be diagnosed by a technician.
Advertisements
Repair Difficulty
Easy
2/5