F.32
Vaillant
Fan Motor Fault / Fan Speed Error
F.32 displayed, fan does not run or runs erratically, boiler does not ignite
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective fan motor, Blocked fan or flue causing overload, Loose or damaged fan wiring, Faulty fan speed control on PCB
How to Fix / Troubleshooting
Safety: Isolate power and gas. Do not operate the boiler with a known fan fault.
Checks:
- Listen for the fan at startup; absence of sound suggests it is not running.
- Inspect the flue terminal for obstructions that could overload the fan.
- Access the fan (qualified personnel) and check for debris or seized bearings; the impeller should spin freely by hand with power off.
- Check the fan connector and wiring harness for secure connection and damage.
Repair: Replace the fan assembly if it is noisy, seized, or electrically open/shorted. PCB fan control faults require board replacement by a professional.
Advertisements
Repair Difficulty
Hard