F.71
Vaillant
Flow/Return Sensor Plausibility Fault
F.71 displayed, flow and return temperatures appear identical or unrealistic
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Flow and return NTCs swapped, One of the NTC sensors faulty, Wiring harness cross-connected, PCB sensor evaluation error
How to Fix / Troubleshooting
Safety: Isolate power before working on sensors.
Steps:
- Verify that the flow NTC is installed on the flow pipe and the return NTC on the return pipe as per Vaillant diagrams.
- Check that each sensor is connected to the correct PCB terminal.
- Measure resistance of both NTCs and compare to specification; replace any faulty sensor.
If wiring and sensors are correct but F.71 persists, the PCB may be defective and should be replaced by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Flow NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements