E06
Viadrus Return or DHW Temperature Sensor Fault

Furnace locks out with E06, domestic hot water (if equipped) overheats or is cold, temperature readings fluctuate.

Advertisements

Possible Causes

Failed return NTC sensor, Failed DHW cylinder NTC sensor (on Viadrus systems with indirect cylinder), Loose sensor connection, Shorted sensor cable due to moisture

How to Fix / Troubleshooting

Safety: Disconnect power before removing any sensor covers or accessing the control board.

  • Identify which sensor: Consult the Viadrus manual to see whether E06 refers to the return NTC or DHW NTC on your specific model.
  • Visual inspection: Locate the relevant NTC sensor on the return pipe or DHW cylinder pocket. Check for damaged insulation, signs of overheating, or water ingress at the cable entry.
  • Test resistance: Disconnect the sensor and measure its resistance at room temperature. Compare to the Viadrus NTC chart. Replace the sensor if readings are out of range.
  • Check wiring route: Ensure the sensor cable is not routed alongside mains cables or pump power cables, which can induce noise. Re‑route if necessary and secure with clips.
  • Replace sensor: If faulty, install a genuine Viadrus NTC sensor of the same rating. Insert fully into the pocket and secure with the clip or screw provided.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Return NTC Temperature Sensor