E16
Viadrus Fan Speed / Tachometer Fault

Display shows E16, no burner operation, and the fan may not start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective flue gas fan tachometer sensor, Blocked or stiff fan impeller, Broken fan speed feedback wire, Faulty fan control circuit on main board

How to Fix / Troubleshooting

Safety: Disconnect power before touching the fan or wiring.

  • Spin test: Remove the fan cover and gently spin the fan wheel by hand. It should rotate freely without scraping. If stiff, replace the fan assembly.
  • Clean fan: Remove dust and soot from the fan blades and housing with a soft brush and vacuum. A heavily imbalanced fan can cause speed errors.
  • Check tachometer wiring: Identify the tachometer (speed feedback) wires from the fan to the control board. Inspect for damage and ensure connectors are fully seated.
  • Fan replacement: If the fan does not reach the required speed or the tachometer signal is absent, replace the complete flue gas fan unit with a Viadrus‑approved part.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flue Gas Fan Assembly
Check Price on Amazon

We may earn a commission from links on this page.