Viadrus
Insufficient Heat Output / Poor Circulation
Furnace runs but radiators remain cold or only lukewarm, burner cycles frequently.
Advertisements
Possible Causes
Circulation pump on Viadrus furnace stuck on low speed, Air trapped in radiators, Clogged system filter or strainer, Incorrectly set mixing valve
How to Fix / Troubleshooting
Safety: Allow system to cool before bleeding radiators or opening filters.
- Bleed radiators: Starting with the highest radiators, use a bleed key to release trapped air until water flows steadily. Monitor system pressure and top up as needed.
- Check pump speed: Locate the circulation pump and verify its speed setting. Increase one step if the system is large or distant from the Viadrus furnace.
- Clean filter: Isolate and clean any Y‑strainer or magnetic filter on the return line. Remove sludge and reinstall.
- Mixing valve setting: If a 3‑way or 4‑way mixing valve is installed, ensure it is not set too low. Adjust gradually while monitoring radiator temperature.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements