06
Vokera Return Temperature Sensor Fault

Display shows 06, furnace may run erratically or not at all

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective return NTC sensor, Damaged sensor cable, Poor connector contact, PCB fault

How to Fix / Troubleshooting

Safety: Turn off power before working on the appliance.

  • Locate return sensor: The return NTC is usually mounted on the return pipe entering the heat exchanger.
  • Check wiring: Inspect the cable from the sensor to the control board for cuts, abrasions, or signs of overheating. Reseat connectors.
  • Visual inspection: Ensure the sensor is firmly attached to the pipe and not hanging loose, which can cause incorrect readings.
  • Replace if faulty: If the sensor is physically damaged or tests out of range, replace it with the correct Vokera return NTC sensor.
  • If error persists: A technician should test the PCB sensor input circuit.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Return NTC Temperature Sensor