23
Vokera
Flow Sensor Out of Range / Calibration Error
Code 23, furnace stops and may show abnormal temperature readings
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect sensor fitted, Poor thermal contact, Scale build-up on sensor pocket, PCB misreading
How to Fix / Troubleshooting
Safety: Turn off power and allow system to cool.
- Verify sensor type: Confirm that the installed flow NTC sensor is the correct Vokera part for this model.
- Check mounting: Ensure the sensor is fully inserted into its pocket or firmly clipped to the pipe with thermal paste if specified.
- Descale pocket (qualified persons): If the sensor sits in a pocket, remove it and inspect for scale or sludge. Clean the pocket carefully and refit.
- Reset and monitor: After reassembly, reset the furnace and monitor temperature readings. If the error returns, PCB diagnostics are required.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Flow NTC Temperature Sensor
Check Price on Amazon