41
Vokera
Air Pressure Switch Closed When Should Be Open
Display shows 41, furnace may attempt to start with fan off or at wrong time
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck air pressure switch contacts, Shorted switch wiring, Incorrect tubing connection
How to Fix / Troubleshooting
Safety: Turn off power before inspection.
- Check tubing connections: Verify that the high and low pressure ports on the switch are connected correctly to the fan or flue hood.
- Inspect for water in tubes: Drain any condensate that may be holding the switch closed.
- Test switch: Disconnect one tube and see if the code changes after reset. If the switch remains indicated as closed, it is likely stuck and must be replaced.
- Replace switch: Fit a new Vokera air pressure switch of the correct rating.