F02
Westinghouse Blower motor fault / no blower operation

Furnace shows F02 and the indoor blower does not run in heat or fan-only mode.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ECM blower motor module, Open blower windings on PSC motor, Defective blower run capacitor (PSC), Loose blower harness at IFC

How to Fix / Troubleshooting

Safety: Turn off power at the breaker and service switch. Blower compartment edges can be sharp; wear gloves.

Steps:

  • Remove the blower compartment door and locate the indoor blower assembly.
  • Check the blower motor harness plug at the IFC and at the motor for secure connection.
  • For PSC motors: Inspect the run capacitor (metal can) for bulging or leaking. Replace with the same µF rating and voltage if defective.
  • Try spinning the blower wheel by hand; it should rotate freely. If seized or very stiff, the motor bearings may have failed.
  • Restore power and call for fan-only at the thermostat. If the motor hums but does not start, suspect a bad capacitor or motor.
  • If your Westinghouse furnace uses an ECM motor and F02 persists, the ECM module or motor assembly likely needs replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Blower Motor Assembly