Westinghouse Thermostat or control short cycling

Furnace cycles on and off rapidly (every 1–5 minutes) without maintaining temperature.

Advertisements

Possible Causes

Thermostat located near heat source or supply register, Thermostat anticipator or cycle rate set incorrectly, Loose thermostat wiring causing intermittent call, Oversized furnace for the space

How to Fix / Troubleshooting

Steps:

  • Check thermostat location; it should be away from direct sunlight, supply registers, and exterior doors.
  • Ensure thermostat is firmly mounted and level (for older mechanical models).
  • Inspect thermostat wiring for loose connections at both thermostat and furnace.
  • Review thermostat settings for cycle rate or heat anticipator; adjust according to thermostat manual for gas forced-air systems.
  • If short cycling persists, a professional should evaluate furnace sizing and ductwork.