A1
Worcester Bosch
Low System Water Pressure
Boiler shows A1 and stops, often associated with low or no water pressure.
Advertisements
Possible Causes
System pressure below minimum threshold, Leak in central heating circuit, Faulty pressure sensor, Recently bled radiators without repressurising
How to Fix / Troubleshooting
Safety first: Ensure the boiler is cool before repressurising. Do not exceed 2.0 bar when cold.
- Check pressure gauge: If the gauge reads below 1.0 bar, repressurise using the filling loop or Worcester Bosch keyless filling link according to the user manual.
- Look for leaks: Inspect visible pipework, radiators, and the boiler underside for signs of water leaks. If a leak is found, isolate and call an engineer.
- Reset the boiler: Once pressure is restored to 1.0–1.5 bar, reset the boiler and check operation.
- Engineer checks: If pressure drops repeatedly, an engineer should check the expansion vessel charge, pressure relief valve, and system for hidden leaks.